Tuolumne County Building and Safety Division
Inspections and Results
 
Permit No. B2019-01606 Permit Type   NEW SFD Site Address   20364 STARR KING DR
Applied   09/06/2019 Applicant   JACK WILSON
Approved   12/03/2019 Owner   ERICKSON, LEE F TR
Issued   12/09/2019 Contractor   JACK WILSON
Parent Permit No.   Description   NEW SFD
  Notes  
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

 12/12/2019UNDERGRD PLBGDan CoughlinCORRECTIONS(12/12/2019 3:24 PM DANC) 1. Underslab plumbing and setbacks okay. 2. Compaction report needed at building pad and footings.

 12/11/2019UNDERFLOOR PLUMBDan CoughlinCANCELLED

 01/28/2020FOUNDATIONDan CoughlinAPPROVED(1/28/2020 3:59 PM DANC) See attached compaction report okay. #4 rebar UFER okay. Setbacks, foundation, piers, underground plumbing okay.

 02/06/2020TEMP POWERDan CoughlinAPPROVED200amp underground okay

 02/14/2020SHEAR/BRACINGDan CoughlinCORRECTIONS&RNail(2/14/2020 3:52 PM DANC) 1. Roof and shear nail only okay to cover. 2. Install all truss bracing and H-1 clips as needed. 3. Install all 6x6 support posts or (4) 2x6's under girder trusses, etc. as needed. 4. Install blocking and strapping per detail on sheet A-8 for openings in type A and B shearwalls. 5. Check all anchor bolts and holdowns at next inspection. CALL FOR RE-INSPECTION OF SHEAR AND ROOF PRIOR TO FRAME INSPECTION ONCE ABOVE IS COMPLETE.

 02/20/2020SHEAR/BRACINGDan CoughlinCORRECTIONS(2/20/2020 2:45 PM DANC) 1. Exterior shear okay. 2. Roof nail okay. 3. Check interior OSB at type "D" shear wall and Gypsum board type "C" at frame and SRN inspections.

 02/28/2020FRAMEDan CoughlinAPPROVED W/COND&Sprinkler(2/28/2020 3:00 PM DANC) 1. Install straps at top plates at left of entry, each end of kitchen beam, and Nw corner of kitchen wall. 2. Okay to insulate. 3. Check gypsum board type "C" at SRN inspection.

 03/04/2020INSULATION WALLSDan CoughlinAPPROVED&Insulation(3/4/2020 1:04 PM DANC) 1. Check interior brace walls type "C" at sheetrock nail.

 03/10/2020SHEETROCK NAILDan CoughlinAPPROVED W/COND(3/10/2020 3:02 PM DANC) 1. Sheetrock nail okay. 2. Eave at garage side may be enchroaching setback: string property line and call for inspection.