Permit No. B2020-00895 Permit Type   RES REPAIRREMODEL Site Address   26425 OLD MONO RD
LONG BARN, CA 95335
Applied   06/23/2020 Applicant   SILVER FERN CONSTRUCTION
Approved   11/13/2020 Owner   NEWLIN, MR & MRS
Issued   11/17/2020 Contractor   SILVER FERN CONSTRUCTION
Parent Permit No.   Description   192SQFT ADDITION, INTERIOR REMODEL
  Notes   (6/23/2020 11:07 AM MC) REROOF, INSTALL GENERATOR, REPLACE HVAC
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

 12/03/2020SETBACKSRick BarrieauAPPROVEDSEE CHRONO 607-0193

 04/22/2021FRAMERick BarrieauCORRECTIONSAM(4/22/2021 10:48 AM RB) 1) Complete the installation of the A-35 clips to blocks in master bed. 2) Ground all metal boxes. 3) Install SDS screws to all ledgers 6 inches on center. 4) Standpipe for washer shall be min, 18 inches tall and max 30 inches tall above its trap. The trap shall be install 6 inches to 18 inches above the floor and the vent shall be taken off above the weir of the trap. 5) The shower trap needs the vent taken off above the weir of the trap. 6) All plumbing needs to be topped out with water after repairs are made. 7) Bath fan to be a min of 3ft away from openable window. 8) All stairs exceed max 7.75 rise.

 04/29/2021REINSPECTIONRick BarrieauCORRECTIONS(4/29/2021 1:57 PM RB) 1) All corrections have been addressed except the plumbing top out proved to show many leaks in the existing plumbing. All old plumbing to be replaced and topped out again. OK TO CONTINUE.

 05/05/2021INSULATION WALLSRick BarrieauAPPROVED

 05/10/2021ROUGH PLBGRick BarrieauAPPROVEDPLUMB TOP OFF - SHEARWALL

 05/13/2021SHEETROCK NAILRick BarrieauAPPROVED& EXT GAS TEST

 07/22/2021FINALRick BarrieauCORRECTIONSAM(7/22/2021 3:25 PM RB) 1) Install grippable handrail, 1.25 to 2 inch round, continuous and set at 34 to 38 inches off tread nose. All stairways, int. ext. Add a landing to the bottom of ext steps from road to deck. 2) Move generator 18 inches off wall and provide noncombustible pad below it per specs. 3) Tighten interior wire guardrail cables. 4) All 15 and 20 amp breakers to be combination AFCI breakers. Exception-bathrooms and exterior plugs. 5) Register title 24 documents online. 6) Fill out waste management forms.

 08/18/2021FINALDan CoughlinCORRECTIONS(8/18/2021 2:02 PM DANC) 1) Install grippable handrail, 1.25 to 2 inch round, continuous and set at 34 to 38 inches off tread nose. All stairways, int. ext. NEED CONTINOUS: NO INTERUPTIONS BY SUPPORTS. Add a landing to the bottom of ext steps from road to deck. INSPECTOR TO RESEARCH. 2) Move generator 18 inches off wall and provide noncombustible pad below it per specs. SPECS CALL FOR NON-COMBUSTIBLE PAD 12 INCHES AROUND GENERATOR: INSPECTOR TO RESEARCH IF CEMENT BOARD OKAY.: CONTRACTOR TOLD PER PHONE: TWO LAYERS CEMENT BOARD WITH STAGGERD JOINTS AND CORROSION PROOF FASTENERS AND METAL EDGING. 4) All 15 and 20 amp breakers to be combination AFCI breakers. Exception-bathrooms and exterior plugs. OKAY WITH EXCEPTION: AFCI AND GFCI AT KITCHEN COUNTERTOPS AND ISLAND.

 09/08/2021FINALDan CoughlinAPPROVED

 12/03/2020PERMANENT POWERRick BarrieauAPPROVED

 05/10/2021SHEAR/BRACINGRick BarrieauAPPROVEDInt shear walls

 04/07/2021ROOF SHEATHINGDan CoughlinAPPROVED W/COND&RNail AM 607-0193(4/7/2021 1:50 PM DANC) 1. Roof nailing and exterior shear only okay to cover. 2. Ensure sill plate nailing 3 16's at 16 inches on center per shearwall schedule. 3. Install SDS in covered porch ledger per approved plan. 4. Vent each rafter bay or completely fill with ridged and batt insulation. 5. Install H-1's or A-35's at upper rafter/top plates. 6. Check interior shear at future inspection.