  Date of Inspection Inspection Type Inspector Result Remarks Notes

 08/05/2020FOOTING AND FORMSKatelyn OgburnCORRECTIONSFOUNDATION(8/5/2020 12:39 PM KO) 1. Have plans and permit on site for inspection.

 08/25/2020FOUNDATIONKatelyn OgburnAPPROVED W/CONDFOOT REBAR(8/25/2020 10:58 AM KO) 1. Perimeter Footing approved with conditions per engineer letter. Chief Building Official to verify items with Engineer prior to pour.

 10/06/2020SHEAR/BRACINGKatelyn OgburnAPPROVED W/COND& SHEAR NAIL(10/6/2020 12:17 PM KO) Ok to continue. 1. Contractor installing clips. Verify block connection and rafter conection to top plate at next inspection.

 11/20/2020ROUGH PLBGDan CoughlinCORRECTIONSROUGH ELEC(11/20/2020 12:51 PM DANC) 1. Complete vent bath fan to exterior 3 foot from building openings. Note humidistate required by final. 2. Min 100CFM fan install kitchen to exterior. 3. Ground screws at metal boxes cieling. 4. Note: AFCI protect all non-bathroom interior outlets. 5. Install electrical for mini-split and crawl space water heater. Note in site shut off needed at water heater. 6. Install TPR water heater drain to exterior. OKAY TO INSULATE.

 12/04/2020SHEETROCK NAILDan CoughlinAPPROVED W/COND(12/4/2020 1:43 PM DANC) See previous correction.

 02/17/2021FINALDan CoughlinCORRECTIONS799-7969(2/17/2021 1:08 PM DANC) 1. Label breakers in panel. 2. Install dead front and exterior cover and plug hole in side of main panel. 3. Paint/protect ABS at roof vents. 4. Cover/protect ABS sewer and PVC water at right side of structure. 5. Install backflow preventer at hose bib. 6. Install handrail at stairs with returns: see handout. 7. Maximum difference in riser height at landing is 3/8ths of 1 inch. Landing shall be 36 inches in direction of travel minimum. 8. Grade away from foundation. 9. Insulate exposed hot and cold water lines above water heater in crawl space: secure top and bottom third of water heater. 10. Install cover at water heater disconnect in crawl space. 11. Install smoke detector.

 07/30/2021FINALRick BarrieauAPPROVED(7/30/2021 3:15 PM RB) No furniture in the shed at this time.

 08/06/2020FOOTING AND FORMSKatelyn OgburnCORRECTIONS(8/6/2020 10:00 AM KO) 1. Clean out footing of loose debris and maintain rebar clearances. 2. Address descending slope close to foundation. 3. Step footings to be a max of 2' steps. 4. Max height of wall from bottom of footing to top is 4'. Back right corner is over 5 feet tall.

 11/30/2020INSULATION WALLSKatelyn OgburnAPPROVED W/COND(11/30/2020 3:10 PM KO) Complete work on #2 and #5 of previous correction.

 07/13/2021FINALKatelyn OgburnCORRECTIONS(7/13/2021 3:39 PM KO) From previous correction: 2. Plug hole in side of main panel. 3. Paint/protect ABS at roof vents. 4. Cover/protect ABS sewer and PVC water at right side of structure. 6. Install handrail at stairs with returns: see handout. 9. Insulate exposed hot water lines in crawl space:. Shed not permitted to be used as a bedroom. remove furnishing or obtain appropriate permit to legalize shed as sleeping space.